Project Description Owner
PQR Tests 0
Displaying 1 - 5 of 5
ID Record Time Parameter Type Reference Welder Project Side Weld Area Pass No Interpass Position Consumable Polarity WFS Volts Amps Arc Time Length Input Speed Travel Speed Stub Length Input Energy Arc Energy Efficiency Heat Input WFS Auto Threshold Diameter Electrode Length Electrode Factor Wire Factor Wire Constant Welding Process Calc Method Project ID
1 21/09/2026 12:55:51 PQR Test Example PQR 1 01 J Smith   Root 1 20 °C 5G/PH ER70S-3 - 1.6mm DC-ve 11.2 68 384 s 163
mm
25.5
mm/min
1.79
kJ/mm
0.6 1.08
kJ/mm
1 39 1.6 mm GTAW(141) Calculated VAT/ROL PQR Tests
2 21/09/2026 13:05:13 PQR Test Example PQR 1 01 J Smith   Hot Pass 2 87 °C 5G/PH ER70S-3 - 1.6mm DC-ve 11 83 291 s 173
mm
35.7
mm/min
1.54
kJ/mm
0.6 0.921
kJ/mm
1 39 1.6 mm GTAW(141) Calculated VAT/ROL PQR Tests
3 21/09/2026 13:17:45 PQR Test Example PQR 1 01 J Smith   Fill 3 121 °C 5G/PH ER70S-3 - 1.6mm DC-ve 11.4 93 315 s 183
mm
34.9
mm/min
1.82
kJ/mm
0.6 1.09
kJ/mm
1 39 1.6 mm GTAW(141) Calculated VAT/ROL PQR Tests
4 21/09/2026 14:02:56 PQR Test Example PQR 1 01 J Smith   Cap 4 50 °C 5G/PH ER70S-3 - 1.6mm DC-ve 11.4 94 278 s 190
mm
41.0
mm/min
1.57
kJ/mm
0.6 0.941
kJ/mm
1 39 1.6 mm GTAW(141) Calculated VAT/ROL PQR Tests
5 21/09/2026 14:14:58 PQR Test Example PQR 1 01 J Smith   Cap 5 81 °C 5G/PH ER70S-3 - 1.6mm DC-ve 11.3 95 283 s 190
mm
40.3
mm/min
1.60
kJ/mm
0.6 0.959
kJ/mm
1 39 1.6 mm GTAW(141) Calculated VAT/ROL PQR Tests